Contactor Switched Automatic PF Correction & Harmonic Filter Capacitor Bank AHPFC
Contactor Switched Automatic Harmonic Power Factor Correction (AHPFC) Panel is centralized reactive power compensation with harmonic mitigation. Automatic control is provided using automatic power factor control relays. The switching of individual steps is through contractors based on the load variation pattern, the minimum and maximum size of steps can be determined to maintain optimum power factor. This will help partly to mitigate the harmonics of the system.
- P.F Correction by automatic switching of contactor based on KVAR requirement.
- With Tuned/Detuned/Tapped Tuned Harmonic Filter Reactors.
- Can be Tuned to 3rd, 5th, 7th, 9th, 11th & 13th order harmonics.
- Safe & smooth switching of capacitor stages with bounce free switching contacts & wear free contact material.
- Patented design to limit inrush currents to <70 times rated current.
Technical Data:
System Voltage
400.....1000 V
Design Voltage
525......2000 V
Rated KVAR
50 KVAR.....6000 KVAR
Switching Module
Contactors
Switching Module
Contactors
Application Standards
Harmonic mitigation as per IEEE 519, 2014/CEA, other utilities norms
Upgrade your Power Systems!
We have always made sure to put quality over profits and will always provide you with the best of products in the market. Contact us to optimise your energy consumption.
More Products
Our product portfolio comprises of a comprehensive collection of the systems including:
(STATCOM/SVG) Static Compensator
STATCOM is a Step less Variable Source of Reactive Power that can provide both Capacitive and Inductive power.
Contactor Switched Automatic Harmonic Filter Panel (AHPFC)
AHPFC Panel is centralized reactive power compensation with harmonic mitigation.
Thyristor Switched Automatic Harmonic Filter Panel (RTPFC)
RTPFC Panels are ideal for eliminating power factor problems in real time for large systems with fluctuating loads.
Active Harmonic Filters
(AHF)
Active Harmonic Filters (AHF) today is designed to calculate the amplitude and phase angle of each harmonic order up to 71st Order Harmonics.
Static VAR Generators (SVG/SVG+)
Clariant Power System Limited’s Static VAR Generator (SVG) is a Step-less Solutions to improve Power Factor.
Hybrid Reactive Power Compensation
Hybrid Broadband Passive Filters (HBPF) is a combination of series and shunt broadband filters.
MV Fixed/Automatic PF Improvement Capacitor Bank (Indoor Type)
With advanced methodology, Clariant Power System Limited design and manufacture customized Power Factor Correction Systems for Medium Voltage & High Voltage applications
Surge Protection Capacitors (SPC)
Surge capacitors work by absorbing the energy from electrical surges, providing protection to the equipment.
Get in Touch